China Good quality Mlz038t4lp9 R404A Air Cooling Compressor for CHINAMFG Compressor air compressor oil

Product Description

 

 

Hermetic piston compressor, MT/Z medium and high temperature compressor specifications
Rated Performance R22,R407C-50HZ
Model Rated Performance* MT-R22 Rated Performance** MTZ-R407C
Capacity(W)  Input Power (KW)  Input current(A)  COP  (W/W) Capacity(W)  Input Power (KW)  Input current(A)  COP  (W/W)
MT/MTZ 18 JA 3881 1.45 2.73 2.68 3726 1.39 2.47 2.68
MT/MTZ 22 JC 5363 1.89 3.31 2.84 4777 1.81 3.31 2.64
MT/MTZ 28 JE 7378 2.55 4.56 2.89 6137 2.35 4.39 2.61
MT/MTZ 32 JF 8064 2.98 4.97 2.70 6941 2.67 5.03 2.60
MT/MTZ 36 JG 9272 3.37 5.77 27.5 7994 3.12 5.71 2.56
MT/MTZ 40 JH 1571 3.85 6.47 2.72 9128 3.61 6.45 2.53
MT/MTZ 44 HJ 11037 3.89 7.37 2.84 9867 3.63 6.49 2.72
MT/MTZ 50 HK 12324 4.32 8.46 2.85 11266 4.11 7.34 2.74
MT/MTZ 56 HL 13771 5.04 10.27 2.73 12944 4.69 8.36 2.76
MT/MTZ 64 HM 15820 5.66 9.54 2.79 14587 5.25 9.35 2.78
MT/MTZ 72 HN 17124 6.31 10.54 2.71 16380 5.97 10.48 2.74
MT/MTZ 80 HP 19534 7.13 11.58 2.74 18525 6.83 11.83 2.71
MT/MTZ 100 HS 23403 7.98 14.59 2.93 22111 7.85 13.58 2.82
MT/MTZ 125 HU 3571 10.66 17.37 2.85 29212 10.15 16.00 2.88
MT/MTZ 144 HV 34340 11.95 22.75 2.87 32934 11.57 18.46 2.85
MT/MTZ 160 HW 38273 13.39 22.16 2.86 37386 13.28 21.40 2.82
MTM/MTZ200 HSS 46807 15.97 29.19 2.93 43780 15.54 26.90 2.82
MTM/MTZ250HUU 6 0571 21.33 34.75 2.85 57839 20.09 31.69 2.88
MTM/MTZ288 HVV 68379 23.91 45.50 2.87 65225 22.92 36.56 2.85
MTM/MTZ 320 HWW 76547 26.79 44.32 2.86 74571 26.30 42.37 2.81

 

Rated Performance*High Efficiency CompressorR22-50HZ
Model Capacity/(W) Input Power (KW) Inputcuprret/(A) COP(W/W)
MT 45 HJ 10786 3.62 6.86 2.98
MT 51 HK 12300 4.01 7.86 3.07
MT 57 HL 13711 4.54 9.24 3.02
MT 65 HM 15763 5.23 8.81 3.01
MT 73 HN 17863 5.98 9.99 2.99
MT 81 HP 25718 6.94 11.27 2.93

R134a,R404A,R507-50Hz
 Model Rated Performance* R134A Rated Performance**R404A,R507-50HZ
Capacity(W)  Input Power (KW)  Input current(A)  COP  (W/W) Capacity(W)  Input Power (KW)  Input current(A)  COP  (W/W)
MT/MTZ 18 JA 2553 0.99 2.19 2.58 1865 1.2 2.47 1.56
MT/MTZ22 JC 3352 1.20 2.51 2.80 2673 1.56 2.96 1.71
MT/MTZ 28 JE 4215 1.53 3.30 2.75 3343 1.95 3.80 1.72
MT/MTZ 32 JF 4951 1.87 3.94 2.65 3747 2.28 4.51 1.64
MT/MTZ 36 JG 6005 2.13 4.09 2.81 4371 2.66 4.91 1.64
MT/MTZ 40 JH 6398 2.33 4.89 2.74 4889 3.00 5.36 1.63
MT/MTZ 44 HJ 6867 2.52 5.65 2.72 5152 3.16 6.37 1.63
MT/MTZ 50 HK 8071 2.88 5.50 2.80 6152 3.61 6.53 1.70
MT/MTZ 56 HL 9069 3.21 5.83 2.82 7001 4.00 7.07 1.75
MT/MTZ 64 HM 1571 3.62 6.96 2.86 8132 4.54 8.30 1.79
MT/MTZ 72 HP 11853 4.01 7.20 2.96 9153 4.99 8.64 1.84
MT/MTZ 80 HP 13578 4.63 8.45 2.93 10524 5.84 10.12 1.80
MT/MTZ 100 HS 15529 5.28 10.24 2.94 12571 6.83 12.16 1.76
MT/MTZ 125 HU 19067 6.29 10.80 3.03 15714 8.53 13.85 1.84
MT/MTZ 144 HV 23620 7.83 13.78 3.02 18076 9.74 16.25 1.86
MT/MTZ 160 HW 25856 8.57 14.67 3.02 25713 11.00 17.94 1.84
MTM/MTZ200 HSS 3571 10.45 20.28 2.94 23800 13.53 24.06 1.76
MTM/MTZ 250 HUU 37746 12.45 21.38 3.03 31121 16.88 27.43 1.84
MTM/MTZ288 HVV 46773 15.49 27.29 3.02 35779 19.28 32.18 1.86
MTM/MTZ 320 HWW 51169 16.98 29.06 3.01 40093 21.76 35.51 1.84

 

50HZ DATA  
Model  50Hz Nominal Cooling Capacity/Capacity Input Power COP E.E.R. c Displacement Displacement Injection flow d Net.W
TR W Btu/h KW W/W Btu/h/W cm³/rev m3/h dm3 kg
R22 Single Sm084 7 20400 69600 6.12 3.33 11.4 114.5 19.92 3.3 64
SM090 7.5 21800 74400 6.54 3.33 11.4 120.5 20.97 3.3 65
SM100 8 23100 79000 6.96 3.33 11.3 127.2 22.13 3.3 65
SM110 9 25900 88600 7.82 3.32 11.3 144.2 25.09 3.3 73
SM112 9.5 27600 94400 7.92 3.49 11.9 151.5 26.36 3.3 64
SM115 9.5 28000 95600 8.31 3.37 11.5 155.0 26.97 3.8 78
SM120 10 35710 157100 8.96 3.36 11.5 166.6 28.99 3.3 73
SM124 10 31200 106300 8.75 3.56 12.2 169.5 29.5 3.3 64
SM125 10 35710 157100 8.93 3.37 11.5 166.6 28.99 3.8 78
SM147 12 36000 123000 10.08 3.58 12.2 193.5 33.7 3.3 67
SM148 12 36100 123100 10.80 3.34 11.4 199.0 34.60 3.6 88
SM160 13 39100 133500 11.60 3.37 11.5 216.6 37.69 4.0 90
SM161 13 39000 133200 11.59 3.37 11.5 216.6 37.69 3.6 88
SM175 14 42000 143400 12.46 3.37 11.5 233.0 40.54 6.2 100
SM/SY185 15 45500 155300 13.62 3.34 11.4 249.9 43.48 6.2 100
SY240 20 61200 2 0571 0 18.20 3.36 11.5 347.8 60.50 8.0 150
SY300 25 78200 267000 22.83 3.43 11.7 437.5 76.10 8.0 157
SY380 30 94500 322700 27.4 3.46 11.8 531.2 92.40 8.4 158
R107C Single SZ084 7 19300 66000 6.13 3.15 10.7 114.5 19.92 3.3 64
SZ090 7.5 20400 69600 6.45 3.16 10.8 120.5 20.97 3.3 65
SZ100 8 21600 73700 6.84 3.15 10.8 127.2 22.13 3.3 65
SZ110 9 24600 84000 7.76 3.17 10.8 144.2 25.09 3.3 73
SZ115 9.5 26900 91700 8.49 3.16 10.8 155.0 26.97 3.8 78
SZ120 10 28600 97600 8.98 3.18 10.9 166.6 28.99 3.3 73
SZ125 10 28600 97500 8.95 3.19 10.9 166.6 28.99 3.8 78
SZ148 12 35100 119800 10.99 3.19 10.9 199.0 34.60 3.6 88
SZ160 13 38600 131800 11.77 3.28 11.2 216.6 37.69 4.0 90
SZ161 13 37900 129500 11.83 3.21 10.9 216.6 37.69 3.6 88
SZ175 14 45710 136900 12.67 3.17 10.8 233.0 40.54 6.2 100
SZ185 15 43100 147100 13.62 3.16 10.8 249.9 43.48 6.2 100
SZ240 20 59100 201800 18.60 3.18 10.9 347.8 60.50 8.0 150
SZ300 25 72800 248300 22.70 3.20 10.9 437.5 76.10 8.0 157
SZ380 30 89600 305900 27.60 3.25 11.1 431.2 92.40 8.4 158

Model Nominal Cooling Capacity 60Hz Nominal Cooling Capacity/Capacity Input Power maximum rated current COP  Displacement  Displacement  Injection flow Net.W
TR W Btu/h kW MCC COP W/W EERBtu/h/W cmVrev m3/h dm3 kg
R22 HRM032U4 2.7 7850 26790 2.55 9.5 3.08 10.5 43.8 7.6 1.06 31
HRM034U4 2.8 8350 28490 2.66 9.5 3.14 10.5 46.2 8.03 1.06 31
HRM038U4 32 9240 31520 2.94 10.0 3.14 10.7 46.2 8.03 1.06 31
HRM040U4  3.3 9710 33120 2.98 10 3.26 11.1 54.4 9.47 1.06 31
HRM042U4 35 10190 34770 3.13 11.0 3.26 11.1 57.2 9.95 1.06 31
HRM045U4 3.8 10940 37310 3.45 12 3.17 10.8 61.5 10.69 1.33 31
HRM047U4 3.9 11500 39250 3.57 12.0 3.23 11.0 64.1 11.15 1.33 31
HRM048U4 4 11510 39270 3.57 12.5 3.23 11 64.4 11.21 1.57 37
HRM051T4 4.3 12390 44280 3.67 13.0 3.37 11.5 68.8 11.98 1.57 37
HRM051U4 4.3 12800 43690 3.83 13 3.34 11.4 68.8 11.98 1.57 37
HRM054U4 4.5 13390 45680 3.97 13.1 3.37 11.5 72.9 12.69 1.57 37
HRM058U4 4.8 14340 48930 4.25 15 3.37 11.5 78.2 13.6 1.57 37
HRM060T4 5.0 14570 49720 4.28 15.0 3.40 11.6 81.0 14.09 1.57 37
HRM060U4 5.0  14820 5 0571 4.4 15 3.37 11.5 81 14.09 1.57 37
HLM068T4 5.7 16880 57580 5.00 15.0 3.37 11.5 93.1 16.20 1.57 37
HLM072T4 6.0  17840 6 0571 5.29 15 3.37 11.5 98.7 17.2 1.57 37
HLM075T4 6.3 18430 62880 5.37 16.0 3.43 11.7 102.8 17.88 1.57 37
HLM081T4 6.8 19890 67880 5.8 17 3.43 11.7 110.9 19.3 1.57 37
HCM094T4 7.8 23060 78670 6.80 21.0 3.39 11.6 126.0 21.93 2.66 44
HCM109T4 9.1 26690 91070 7.77 24 3.43 11.7 148.8 25.89 2.66 44
HCM120T4 10.0 29130 99390 8.51 25.0 3.42 11.7 162.4 28.26 2.66 44
R407C HRP034T4  2.8 7940 27080 2.68 9.5 2.96 10.1 46.2 8 1.06 31
HRP038T4 3.2 8840 30150 2.82 11 3.14 10.7 51.6 8.98 1.06 31
HRP040T4 3.3 9110 31080 3.14 11.5 2.9 9.9 54.4 9.47 1.06 31
HRP042T4 3.5 9580 32680 3.3 10 2.9 9.9 57.2 9.95 1.06 31
HRP045T4 3.8 1571 36890 3.58 12 3.02 10.3 61.5 10.69 1.33 31
HRP047T4 3.9 11130 37980 3.69 12 3.02 10.3 64.1 11.15          1.33 31
HRP048T4 4.0  11100 37880 3.35 12 3.31 11.3 64.4 1L21 1.57 37
HRP051T4 4.3 12120 41370 3.83 13 3.17 10.8 68.8 11.98 1.57 37
HRP054T4 4.5 12570 42880 3.97 12.5 3.17 10.8 72.8 12.66 1.57 37
HRP058T4 4.8 13470 45970 4.25 14.0 3.17 10.8 78.2 13.6 1.57 37
HRP060T4 5.0  13860 47280 4.26 15 3.25 11.1 81 14.09 1.57 37
HLP068T4 5.7 15700 53560 5.10 15.0 3.08 10.5 93.1 16.20 1.57 37
HLP072T4 6.0  16810 57350 5.16 15 3.26 11.1 98.7 17.17 1.57 37
HLP075T4 6.3 18040 61550 5.54 16.0 3.26 11-1 102.8 17.88 1.57 37
HLP081T4 6.8 18600 63470 5,66 17 3.28 11,2 110,9 19,30 1,57 37
HCP094T4 7.8 21590 73660 6.63 21.0 3.26 11.1 126.0 21.93 2.66 44
HCP109T4 9.1 25070 85550 7.77 24 3.23 11 148.8 25.89 2.66 44
HCP120T4 10.0 27370 93400 8.47 25.0 3.23 11.0 162.4 28.26 2.66 44
R410A HRH571U4 2.4 7120 24310 2.43 10 2.93 10 27.8 4.84 1.06 31
HRH031U4 26 7530 25710 2.67 10.0 2.82 9.62 29.8 5.19 1.06 31
HRH032U4 2.7 7670 26170 2.75 10 2.79 9.51 30.6 5.33 1.06 31
HRH034U4 2.8 8500 29000 2.90 10.0 2.93 10.0 33.3 5.75 1.06 31
HRH036U4 3 8820 30110 3.13 10 2.82 9.62 34.7 6.04 1.06 31
HRH038U4 3.2 9250 31560 3.35 12.0 2.76 9.41 36.5 6.36 1.06 32
HRH040U4 3.3 15710 34810 3.58 12 2.85 9.72 39.6 6.9 1.33 32
HRH041U4 3.3 10050 34300 3.43 12.5 2.93 10 39.3 6.8 1.57 37
HRH044U4 3.7 1 0571 36940 3.92 13.5 2.76 9.41 42.6 7.41 1.57 37
HRH049U4 4.1 12110 41320 4.04 13.5 2.99 10.22 47.4 8.24 1.57 37
HRH051U4 4.3 12860 43890 4.21 13 3.05 10.42 49.3 5.58 1.57 37
HRH054U4 4.5 13340 45510 4.41 15.0 3.02 10.32 52.1 9.07 1.57 37
HRH056U4 4.7 13830 47200 4.58 15 3.02 1031 54.1 9.42 1.57 37
HLH061T4 5.1 15210 51880 4.89 15.0 3.11 1061 57.8 10.10 1.57 37
HLH068T4  5.7 16880 57610 5.26 19 3.21 1096 64.4 11.21 1.57 37
HLJ072T4 6.0 17840 60900 5.56 19.0 3.21 11.0 68.0 11.82 1.57 37
HLJ075T4  6.3 18600 63490 5.77 18 3.22 11 70.8 12.32 1.57 37
HLJ083T4 6.9 20420 69690 6.28 19.0 3.25 Hl 78.1 13.59 1.57 37
HCJ090T4 7.5 22320 76190 7.19 19 3.11 10.6 86.9 15.11 2.66 44
HCJ105T4 8.8 26100 89090 8.25 25.0 3.16 10.8 101.6 17.68 2.66 44
HCJ120T4 10 29610 157180 9.53 27 3.11 10.6 116.4 20.24 2.66 44

 

Model HP Voltage
MLM019T5LP9 2.5 220-240V-1-50HZ
MLM571T5LP9 3 220-240V-1-50HZ
MLM026T5LP9 3.5 220-240V-1-50HZ
MLM015T4LP9 2 380-415V-3-50Hz&460V-3-60Hz
MLM019T4LP9 2.5 380-415V-3-50Hz&460V-3-60Hz
MLM571T4LP9 3 380-415V-3-50Hz&460V-3-60Hz
MLM026T4LP9 3.5 380-415V-3-50Hz&460V-3-60Hz
MLM030T4LC9 4 380-415V-3-50Hz&460V-3-60Hz
MLM038T4LC9 5 380-415V-3-50Hz&460V-3-60Hz
MLM045T4LC9 6 380-415V-3-50Hz&460V-3-60Hz
MLM048T4LC9 7 380-415V-3-50Hz&460V-3-60Hz
MLM058T4LC9 7.5 380-415V-3-50Hz&460V-3-60Hz
MLM066T4LC9 9 380-415V-3-50Hz&460V-3-60Hz
MLM076T4LC9 10 380-415V-3-50Hz&460V-3-60Hz
*MLM series general-purpose lubricating oil is AB alkyl benzene oil, the refrigerant is R22.
 
Model HP Voltage
MLZ019T5LP9 2.5 220-240V-1-50HZ
MLZ571T5LP9 3 220-240V-1-50HZ
MLZ026T5LP9 3.5 220-240V-1-50HZ
MLZ015T4LP9 2 380-415V-3-50Hz&460V-3-60Hz
MLZ019T4LP9 2.5 380-415V-3-50Hz&460V-3-60Hz
MLZ571T4LP9 3 380-415V-3-50Hz&460V-3-60Hz
MLZ026T4LP9 3.5 380-415V-3-50Hz&460V-3-60Hz
MLZ030T4LC9 4 380-415V-3-50Hz&460V-3-60Hz
MLZ038T4LC9 5 380-415V-3-50Hz&460V-3-60Hz
MLZ045T4LC9 6 380-415V-3-50Hz&460V-3-60Hz
MLZ048T4LC9 7 380-415V-3-50Hz&460V-3-60Hz
MLZ058T4LC9 7.5 380-415V-3-50Hz&460V-3-60Hz
MLZ066T4LC9 9 380-415V-3-50Hz&460V-3-60Hz
MLZ076T4LC9 10 380-415V-3-50Hz&460V-3-60Hz
*MLM series general-purpose lubricating oil is PVE ugly oil, refrigerant R404A/R134A/R507/R22

Archean refrigeration has been focusing on the refrigeration industry for more than 10 years. The compressors are sold all over the world and have been well received. The company has accumulated strong experience in the compressor market, rich technical support, and a satisfactory one-stop procurement solution. You can rest assured You don’t need to worry about this series, from placing an order to receiving the goods. We provide a complete solution to serve customers well, which is our purpose of hospitality.

 

Installation Type: Movable Type
Lubrication Style: Lubricated
Cylinder Position: Vertical
Model: Sh180b4aae
Samples:
US$ 100/Piece
1 Piece(Min.Order)

|
Request Sample

Customization:
Available

|

air compressor

How are air compressors employed in the petrochemical industry?

Air compressors play a vital role in the petrochemical industry, where they are employed for various applications that require compressed air. The petrochemical industry encompasses the production of chemicals and products derived from petroleum and natural gas. Here’s an overview of how air compressors are utilized in the petrochemical industry:

1. Instrumentation and Control Systems:

Air compressors are used to power pneumatic instrumentation and control systems in petrochemical plants. These systems rely on compressed air to operate control valves, actuators, and other pneumatic devices that regulate processes such as flow control, pressure control, and temperature control. Compressed air provides a reliable and clean source of energy for these critical control mechanisms.

2. Pneumatic Tools and Equipment:

Petrochemical plants often utilize pneumatic tools and equipment for various tasks such as maintenance, repair, and construction activities. Air compressors supply the necessary compressed air to power these tools, including pneumatic drills, impact wrenches, grinders, sanders, and painting equipment. The versatility and convenience of compressed air make it an ideal energy source for a wide range of pneumatic tools used in the industry.

3. Process Air and Gas Supply:

Petrochemical processes often require a supply of compressed air and gases for specific applications. Air compressors are employed to generate compressed air for processes such as oxidation, combustion, and aeration. They may also be used to compress gases like nitrogen, hydrogen, and oxygen, which are utilized in various petrochemical reactions and treatment processes.

4. Cooling and Ventilation:

Petrochemical plants require adequate cooling and ventilation systems to maintain optimal operating conditions and ensure the safety of personnel. Air compressors are used to power cooling fans, blowers, and air circulation systems that help maintain the desired temperature, remove heat generated by equipment, and provide ventilation in critical areas.

5. Nitrogen Generation:

Nitrogen is widely used in the petrochemical industry for applications such as blanketing, purging, and inerting. Air compressors are utilized in nitrogen generation systems, where they compress atmospheric air, which is then passed through a nitrogen separation process to produce high-purity nitrogen gas. This nitrogen is used for various purposes, including preventing the formation of explosive mixtures, protecting sensitive equipment, and maintaining the integrity of stored products.

6. Instrument Air:

Instrument air is essential for operating pneumatic instruments, analyzers, and control devices throughout the petrochemical plant. Air compressors supply compressed air that is treated and conditioned to meet the stringent requirements of instrument air quality standards. Instrument air is used for tasks such as pneumatic conveying, pneumatic actuators, and calibration of instruments.

By employing air compressors in the petrochemical industry, operators can ensure reliable and efficient operation of pneumatic systems, power various tools and equipment, support critical processes, and maintain safe and controlled environments.

air compressor

What safety precautions should be taken when working with compressed air?

Working with compressed air requires adherence to certain safety precautions to prevent accidents and ensure the well-being of individuals involved. Here are some important safety measures to consider:

1. Personal Protective Equipment (PPE):

Wear appropriate PPE, including safety goggles or a face shield to protect eyes from flying debris or particles, hearing protection to reduce noise exposure, and gloves to safeguard hands from potential hazards.

2. Compressed Air Storage:

Avoid storing compressed air in containers that are not designed for this purpose, such as soda bottles or makeshift containers. Use approved and properly labeled air storage tanks or cylinders that can handle the pressure and are regularly inspected and maintained.

3. Pressure Regulation:

Ensure that the air pressure is regulated to a safe level suitable for the equipment and tools being used. High-pressure air streams can cause serious injuries, so it is important to follow the manufacturer’s recommendations and never exceed the maximum allowable pressure.

4. Air Hose Inspection:

Regularly inspect air hoses for signs of damage, such as cuts, abrasions, or leaks. Replace damaged hoses immediately to prevent potential accidents or loss of pressure.

5. Air Blowguns:

Exercise caution when using air blowguns. Never direct compressed air towards yourself or others, as it can cause eye injuries, hearing damage, or dislodge particles that may be harmful if inhaled. Always point blowguns away from people or any sensitive equipment or materials.

6. Air Tool Safety:

Follow proper operating procedures for pneumatic tools. Ensure that tools are in good working condition, and inspect them before each use. Use the appropriate accessories, such as safety guards or shields, to prevent accidental contact with moving parts.

7. Air Compressor Maintenance:

Maintain air compressors according to the manufacturer’s guidelines. Regularly check for leaks, clean or replace filters, and drain moisture from the system. Proper maintenance ensures the safe and efficient operation of the compressor.

8. Training and Education:

Provide adequate training and education to individuals working with compressed air. Ensure they understand the potential hazards, safe operating procedures, and emergency protocols. Encourage open communication regarding safety concerns and implement a culture of safety in the workplace.

9. Lockout/Tagout:

When performing maintenance or repairs on compressed air systems, follow lockout/tagout procedures to isolate the equipment from energy sources and prevent accidental startup. This ensures the safety of the individuals working on the system.

10. Proper Ventilation:

Ensure proper ventilation in enclosed areas where compressed air is used. Compressed air can displace oxygen, leading to a potential risk of asphyxiation. Adequate ventilation helps maintain a safe breathing environment.

By adhering to these safety precautions, individuals can minimize the risks associated with working with compressed air and create a safer work environment.

air compressor

How is air pressure measured in air compressors?

Air pressure in air compressors is typically measured using one of two common units: pounds per square inch (PSI) or bar. Here’s a brief explanation of how air pressure is measured in air compressors:

1. Pounds per Square Inch (PSI): PSI is the most widely used unit of pressure measurement in air compressors, especially in North America. It represents the force exerted by one pound of force over an area of one square inch. Air pressure gauges on air compressors often display pressure readings in PSI, allowing users to monitor and adjust the pressure accordingly.

2. Bar: Bar is another unit of pressure commonly used in air compressors, particularly in Europe and many other parts of the world. It is a metric unit of pressure equal to 100,000 pascals (Pa). Air compressors may have pressure gauges that display readings in bar, providing an alternative measurement option for users in those regions.

To measure air pressure in an air compressor, a pressure gauge is typically installed on the compressor’s outlet or receiver tank. The gauge is designed to measure the force exerted by the compressed air and display the reading in the specified unit, such as PSI or bar.

It’s important to note that the air pressure indicated on the gauge represents the pressure at a specific point in the air compressor system, typically at the outlet or tank. The actual pressure experienced at the point of use may vary due to factors such as pressure drop in the air lines or restrictions caused by fittings and tools.

When using an air compressor, it is essential to set the pressure to the appropriate level required for the specific application. Different tools and equipment have different pressure requirements, and exceeding the recommended pressure can lead to damage or unsafe operation. Most air compressors allow users to adjust the pressure output using a pressure regulator or similar control mechanism.

Regular monitoring of the air pressure in an air compressor is crucial to ensure optimal performance, efficiency, and safe operation. By understanding the units of measurement and using pressure gauges appropriately, users can maintain the desired air pressure levels in their air compressor systems.

China Good quality Mlz038t4lp9 R404A Air Cooling Compressor for CHINAMFG Compressor   air compressor oilChina Good quality Mlz038t4lp9 R404A Air Cooling Compressor for CHINAMFG Compressor   air compressor oil
editor by CX 2023-12-09